Cellular Imaging
Filtered Search Results
Agilent BioTek Cytation 5 Multi-Mode Only Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cytation 5 combines automated microscopy and conventional microplate detection in a configurable, upgradable platform. For Research Use Only. Not for use in diagnostic procedures.
| Height (Metric) | 44.5 cm |
|---|---|
| Depth (English) | 20.2 in. |
| Width (English) | 16.4 in. |
| Shaking | Linear, Orbital, Double Orbital |
| Wattage | 250 W max. |
| Absorbance Range | 230 to 999 nm, 1 nm increments |
| Light Source | Xenon Flash; 100 mW 680 nm laser (Alpha Detection) |
| Width (Metric) | 41.6 cm |
| Dynamic Range | Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades |
| Reading Options | End point, kinetic, spectral scanning and well area scanning |
| Accuracy | Monochromator: ±2 nm; Dispenser: ±1 μL or 2% |
| Type | Multi-Mode Only Microplate Reader |
| No. of Dispensers | 2 Syringe Pumps |
| Dispense Volume | 5 to 1000 μL, 1 μL increments |
| For Use With (Equipment) | BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible |
| Depth (Metric) | 51.4 cm |
| Weight (English) | 80 lb. |
| Software | Gen5 Microplate Reader and Imager Software included; Gen5 Image+ and Image Prime software available for full image analysis; Gen5 Secure for 21 CFR Part 11 compliance (option) |
| Certifications/Compliance | CE and TUV marked. RoHS compliant. |
| Temperature Range (Metric) | 4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C) |
| CO2 Concentration Range | 0 to 20% |
| Weight (Metric) | 36.3 kg |
| Height (English) | 17.5 in. |
Agilent BioTek Cytation 1 Cell Imaging Multi-Mode Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
BioTek Cytation 1 cell imaging multi-mode reader combines fluorescence and high contrast brightfield imaging with conventional multi-mode detection. For Research Use Only. Not for use in diagnostic procedures.
| Height (Metric) | 44.5 cm |
|---|---|
| Depth (English) | 20 in. |
| Width (English) | 16.5 in. |
| Shaking | Linear, Orbital, Double Orbital |
| Light Source | Xenon Flash |
| Width (Metric) | 41.9 cm |
| Reading Options | Endpoint, kinetic, area scanning, plate mode inject/read process and well mode inject/read process |
| Type | Cell Imaging Multi-Mode Microplate Reader |
| Depth (Metric) | 50.8 cm |
| Software | Gen5 Microplate Reader and Imager Software |
| Certifications/Compliance | CE and TUV marked. RoHS compliant. |
| Temperature Range (Metric) | Incubation to 45°C |
| O2 Concentration Range | 0 to 19% |
| CO2 Concentration Range | 0 to 20% |
| Height (English) | 17.5 in. |
| Resolution | 0.3 μm/pixel at 20X |
| Plate Type | 6-well to 384-well plates |
Agilent BioTek Cytation 5 Cell Imaging Only Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cytation 5 combines automated microscopy and conventional microplate detection in a configurable, upgradable platform. For Research Use Only. Not for use in diagnostic procedures.
| Height (Metric) | 44.5 cm |
|---|---|
| Depth (English) | 20.2 in. |
| Width (English) | 16.4 in. |
| Contrast Methods | Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast |
| Shaking | Linear, Orbital, Double Orbital |
| Wattage | 250 W max. |
| Objectives | 1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x |
| Width (Metric) | 41.6 cm |
| Dynamic Range | Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades |
| Type | Cell Imaging Only Microplate Reader |
| For Use With (Equipment) | BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible |
| Depth (Metric) | 51.4 cm |
| Weight (English) | 80 lb. |
| Certifications/Compliance | CE and TUV marked. RoHS compliant. |
| Camera | Sony CMOS, 16-bit Gray Scale, Standard or WFOV |
| Temperature Range (Metric) | 4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C) |
| CO2 Concentration Range | 0 to 20% |
| Weight (Metric) | 36.3 kg |
| Height (English) | 17.5 in. |
| Plate Type | Monochromator: 6- to 384-well plates; Filters: 6-to 1536 well plates; Imaging: 6-to 1536 well plates |
Agilent BioTek Hinged Light-blocking Cover
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cover for use with Lionheart LX
Agilent BioTek Lionheart FX Automated Microscope
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Lionheart FX automated microscope is a compact system for a broad range of imaging workflows. For Research Use Only. Not for use in diagnostic procedures.
Agilent BioTek Lionheart LX Automated Microscope
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Lionheart FX automated microscope is a compact system for a broad range of imaging workflows. For Research Use Only. Not for use in diagnostic procedures.
Invitrogen™ HybriSlip™ Hybridization Cover, 40 mm x 22 mm, RNase free
Designed specifically for in situ hybridization
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Invitrogen™ CytoVista™ Coronal Mouse Brain Slicer, 1 mm
This 1 mm coronal mouse brain slicer allows you to easily cut a mouse brain into smaller pieces for easier imaging with objectives that have a limited working distance.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Invitrogen™ InSpeck™ Blue (350/440) Microscope Image Intensity Calibration Kit, 2.5 μm
Provides microsphere standards that generate a series of well-defined fluorescent intensity levels for constructing calibration curves and evaluating sample brightness
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Agilent BioTek Cytation 5 Cell Imaging Multi-Mode Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cytation 5 combines automated microscopy and conventional microplate detection in a configurable, upgradable platform. For Research Use Only. Not for use in diagnostic procedures.
| Height (Metric) | 44.5 cm |
|---|---|
| Depth (English) | 20.2 in. |
| Width (English) | 16.4 in. |
| Contrast Methods | Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast |
| Shaking | Linear, Orbital, Double Orbital |
| Wattage | 250 W max. |
| Objectives | 1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x |
| Absorbance Range | 230 to 999 nm, 1 nm increments |
| Light Source | Xenon Flash; 100 mW 680 nm laser (Alpha Detection) |
| Width (Metric) | 41.6 cm |
| Dynamic Range | Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades |
| Reading Options | End point, kinetic, spectral scanning and well area scanning |
| Accuracy | Monochromator: ±2 nm; Dispenser: ±1 μL or 2% |
| Type | Cell Imaging Multi-Mode Microplate Reader |
| No. of Dispensers | 2 Syringe Pumps |
| Dispense Volume | 5 to 1000 μL, 1 μL increments |
| For Use With (Equipment) | BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible |
| Depth (Metric) | 51.4 cm |
| Weight (English) | 80 lb. |
| Certifications/Compliance | CE and TUV marked. RoHS compliant. |
| Camera | Sony CMOS, 16-bit Gray Scale, Standard or WFOV |
| Temperature Range (Metric) | 4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C) |
| CO2 Concentration Range | 0 to 20% |
| Weight (Metric) | 36.3 kg |
| Height (English) | 17.5 in. |
Corning™ Videodrop
Through the utilization of interferometry in conjunction with microscopy, the Corning™ Microdrop; senses, detects, characterizes, and tracks single nanoparticles in real time.
Invitrogen™ EVOS™ M7000 Imaging System
High-performance, fully automated, inverted, multi-channel fluorescence and transmitted light imaging system. Developed to meet today’s expectations for image quality, user interface interactions, data generation speed and flexibility, and end-user value with just a few clicks.
Invitrogen™ CytoVista™ 10X Wash Buffer
CytoVista 10X Wash Buffer is used in wash steps when performing immunohistochemistry (IHC) or immuno-labeling with tissue or 3D cell culture.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Shipping Condition | Approved for shipment at Room Temperature or on Wet Ice |
|---|---|
| Content And Storage | Store in refrigerator (2°C to 8°C).Use sterile techniques when using. If necessary, sterile-filter through 0.22-μm filter before each use. |
| Reagent Type | Wash Buffer |
| Product Line | CytoVista |
Invitrogen™ CytoVista™ Blocking Buffer
CytoVista Blocking Buffer is used to block non-specific signal while performing immunohistochemistry (IHC) or immuno-labeling with tissue or 3D cell cultures.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Shipping Condition | Approved for shipment at Room Temperature or on Wet Ice |
|---|---|
| Content And Storage | Store in refrigerator (2°C to 8°C).Use sterile techniques when using. If necessary, sterile-filter through 0.22-μm filter before each use. |
| Reagent Type | Binding Buffer |
| Product Line | CytoVista |
Agilent Technologies™ xCELLigence RTCA DP Bundle
Continuously measures cell invasion and migration (CIM) and monitors cell health, behavior, and function using label-free cellular impedance.